SPECIFICATION DRAWING
SHIP OWNER : RIO TINTO
SHIP BUILDER : HANJIN Heavy Industries.
HULL No : P0065/66/67/68/69/70/71/72
KIND OF VESSEL : 205K Bulk Carrier
CLASS : LR

DRAWING FOR APPROVAL

Project No. : NKRSN10006-0044

45,72,73,74.75,76,77

BALLAST WATER TREATMENT SYSTEM
Electro-Cleen™ System (ECS-3000X2)

ASAN FACTORY
[336-833] 25-1 Kwanamri, Inju-myun, Asan-si, Chunchungnamdo, Korea
Tel. +82-41-420-9000(Rep) Fax. +82-41-420-9090

BUSAN OFFICE
[600-816] , 3F Hanjin Shipping Bldg., 79-9 Jungang-Dong, 4-Ga, Jung-Gu, Busan, Korea
Tel. +82-51-603-3500(Rep) Fax. +82-51-603-3535

WORKING

APPROVAL

FINAL

Page 2

System

Title

NKRSN10006-0044
,45,72,73,74,75,76,77Project :

of

1

DWG No.Checked Date Approved

Rev. No Date

Drawn Date

S.U.JU 2011.08.01

Electro-Cleen™ System
Page

Plan History
Rev.no Date

V1.0 2011.08.01 1

ECS - 3000 X 2

S.S CHOI 2011.08.01 H.B.LEE 2011.08.01

Date

Description Page Dwg.By App.By

Page 25

System

Title

8. Control PC (CPC)

of PCU. However, CPC installed at PCU can only be used when Master CPC is out of order.

FMU detects water flow volume in pipe line. After receiving water flow volume from FMU,

FTS measures fresh water and its information is sent to HMI.

9. Flow Meter Unit (FMU)

Project :
NKRSN10006-0044
,45,72,73,74,75,76,77

ECS - 3000 X 2

CPC is operated by HMI(Human Machine Interface) software and it is designed to control master

both automatically and manually. CPC is usually installed at Cargo Control Room and on the front

Electro-Cleen™ System

its signal is sent to PRE to control adequate power control.

10. Conductivity Sensor Unit (CSU)

to HMI automatically to control intensity of voltage.

S.U.JU

11. Fresh water Temperature Sensor (FTS)

During ballasting, CSU measures conductivity of ballast water and its information will be sent

S.S CHOI 2011.08.01 H.B.LEE 2011.08.01 2011.08.01

DWG No.

2
General

Date

V1.0 2011.08.01

Rev.no of

5

Date ApprovedCheckedDateDrawn Date

Page

GDS measures H2 gas created during ballasting. installed at TSU

extracts gas and gas density is inspected by GDS.
If measured gas volume is not normal(more than 3%~4%), GDS sends alarm signal to LOP

to PCU.
If temperature of Fresh water increased over 40℃ or lower than 0℃, FTS sends alarm signal

12. Gas Detector Sensor (GDS)

B-2

Page 26

System

Title

Project :

ECS - 3000 X 2

NKRSN10006-0044
,45,72,73,74,75,76,77

Power
Distributor

part

Power Control Unit
Power Distributor Equipment

- Send alarm signal to control PC when any

disorders are detected

power rectifier part, neutralization part and sensors

- DC10V/3000A

- Detect disorder of input / supply voltage

Maker

Self diagnosable system

- Detect electric status from switchboard

- Save accumulated status data when it is operating

Maker

- 3P high AC 440V input power supply to control part,

Control part

Description

Control PC
(With HMI S/W installed)

- GPS signal analysis

- Ballast water flow meter check and analysis

- Analyse cooling water supply status

- Analyse multi-functional relay working status

- Analyse rectifier working status

Component

- Analyse every sensor movement in RTU

Page

- Remote observation and control

Scope

Electro-Cleen™ System
of

V1.0 2011.08.01 3 5

Rev.no Date
General

Drawn Date Checked Date Approved Date DWG No.

S.S CHOI 2011.08.01 H.B.LEE 2011.08.012011.08.01 S.U.JU

Division

Maker
Sensor

Part

Gas Detector Sensor

Mode Part
Detection

Spare Part
Relay

- Measure concentration of TRO for calibration

Electro-Chamber Unit
Electro-Chamber Module
Electrode Module

Power
Rectifier

Equipment

Fresh water Temperature
Sensor Unit

Conductivity Sensor Unit

TRO Sensor Unit

- Self diagnosable system

Maker

- Disinfects Micro-organisms

- Three Electrode Module(EM)

Electrolysis
part

- Remote controllable system

- I/O power supply status display or Input/Output

- For detection of discharge mode

- Treatment capacity 1000m³/hr

- Checks ballast pump working on/off

power supply status display

- Transmission status display

Rectifier
part

Portable TRO Colorimeter

Maker

- Measure fresh water temperature

- For PRE,PDE,TSU,ANU

- For ECU

on emergency use

Gasket
Lamp and Fuse

- Measure flow rate

- Detect ballast pump working status

- Measure concentration of TRO(TRO sensor system)

- Measure electric conductivity

- For PDE, ANU,TSU
- For ECU

Flow meter Unit Maker

Bolt and Nuts

Maker

Solenoid Valve - For ANU/TSU

- Send alarm signal to LOP when any Chlorine

and Hydrogen hazards are detected

B-3

Page 49

C-21

Page 50

C-22